Skip to content Skip to footer
This diesel generator set is engineered for
applications requiring reliable standby or prime
power in fixed installations.
It is designed with a focus on power continuity,
operational safety, and optimized fuel efficiency,
ensuring stable and consistent performance across
varying load conditions.

Standby

1250 kVA

Prıme

1100 kVA

Fuel Type

DIESEL

Frequency

50 Hz
Technical Specifications Unit Value
Generator Model ALMPE - 1250
Engine Model Perkins / 4008-30TAG3
Fuel Type Diesel
Frequency Hz 50
Voltage V 231 / 400
Power Factor CosØ 0.8
Engine Brand Perkins
Engine Model 4008-30TAG3
Engine Tуpe 4 Stroke Diesel Engine
Number of Cylinders/Configuration 8L
Total Displacement It 30,561
Bore x Stroke mm 160 x 190
Compression Ratio 13,1:1
Engine Speed / Frequency d/dk/Hz 1500/50
Engine Standby Power kWm 1105
Engine Prime Power kWm 997
Aspiration System Turbocharged, Aftercooler
Injection System Direct
Governor Type Electronic
Cooling System Water Cooled
Coolant Capacity lt 140
Cooling Air Flow m3/dk 1350
Lubricating Oil Capacity lt 153
Electrical System VDC 24
Battery Capacity Adet x Ah 2 x 180
Charging Alternator Output A 55
Jacket Water Heater Adet x W 1 x 2000
Combustion Air Flow m3/dk 96
Exhaust Gas Flow m3/dk 240
Exhaust Gas Temperature ºC 482
Fuel Consumption at 100% Load lt/s 244
Fuel Consumption at 75% Load lt/s 188
Fuel Consumption at 50% Load lt/s 120
Number of Phase / Poles 3/4
Excitation System Self Excited
Voltage Regulator Automatic
Voltage Regulation 1%
Insulation Class H
Protection Class IP23
Connection Type Star
Frequency Hz 50
Power Factor Cosø 0,8
Total Harmonic Distortion (No Load)
Output Voltage VAC 231 / 400

Details

Car ID: ALMPE 1250 Transmission: Prime
1100 kVA
Fuel: Stand-by
1250 kVA
Engine: Perkins Mileage: 50 Hz Jeneratör Modeli: ALMPE10

Contacts

Car's agent
Contact admin